Location: .. .. .. PCM30U-OCH with module SDH

PCM30U-OCH with module SDH

PCM30U-OCH_with_SDH_cardSDH_cardThe ASDH plug-in unit is an access unit with a 2x STM1 line ending and 6x E1, 4x Ethernet 10/100 and 1x E3 tributary flows.








Basic characteristics


The ASDH unit is intended for use in the PCM30U-OCH block, where it enables to include within STM1:
  • two E1 flows in NRZ code from a JRx interface unit or a CJAB central unit
  • four E1 flows connected via an RM1 interface
  • four data flows with an Ethernet 10/100 interface
  • one E3 flow connected using an SB1E3 submodule via an RM3 interface or using an OS1, OS2 submodule via an optic interface at a wave length of 1300nm or 1550 nm
  • the unit therefore allows to integrate the PCM30U subscriber interfaces and E1, E3, Ethernet subscriber flows to SDH networks in which it can be used as a terminal muldex or an add-drop muldex, with the possibility of 1+1 APS redundancy
  • synchronisation signal input and output
  • possibility to connect a local supervising channel to the front panel (RS232))
  • possibility to connect a supervising channel to the front panel (Ethernet 10/100)
  • the unit meets ITU-T recommendations of G.664, G.703, G.704, G.707, G.783 G.957, Ethernet-to-SDH schemes of: GFP - G.7041, LCAS - G.7042, and IEEE802.3


Scheme_of_SDH_interfaces

Contact: sales2@ttc.cz